| Coaxial Cables | ||||||||||||
M17/29-RG 59 (RG 59 B/U)
Construction

| Inner conductor | Copper cladsteel(CCS) | Φ0.58±0.03mm |
|---|---|---|
| Dielectric | Lowdensity PE | Φ3.70±0.10mm |
| Outer conductor(shield) | Plain copper | 120x0.15mm |
| Shield coverage | 95% | |
| Sheath | PVC or LSZH | Φ6.20±0.10mm |
Electrical & Mechanical Characteristics
Impedance :75±5Ohm
Nominal capacitance :67pF/m
Velocity of propagation :66%
Insulation resistance :>2000Mohm.Km
Inner conductor resistance :158Ohm/Km
Outer conductor resistance :9.0Ohm/Km
Test/Operatig Voltage(max) :5.0KV/3.5KV
Operating temperature range :-30°C-+70°C
Copper weight :22.4Kg/Km
Cable weight(approx.) :55.8Kg/Km
Screening effectiveness :>55dB
Attenuation
| Frequency(MHz)50 | Attenuation(dB/100m)7.4 | Attenuation(dB/100ft)2.26 |
|---|---|---|
| 100 | 10.7 | 3.26 |
| 200 | 15.7 | 4.79 |
| 400 | 22.7 | 6.92 |
| 500 | 25.7 | 7.84 |
| 600 | 28.7 | 8.75 |
| 860 | 34.8 | 10.61 |
| 1000 | 38 | 11.59 |
Return Loss
| 30-300MHz | >31dB |
|---|---|
| 300-600MHz | >28dB |
| 600-900MHz | >24dB |